• About us
    • Who we are
    • Our Story
  • Certifications
  • Research and innovation projects
  • Work with us
  • Magazine
  • Contact
logo
logo
  • Radiology
    • Dynamic imaging
    • Direct Digital Radiology - Multifunctional Systems
    • Retrofit - Digital Panels
    • Mammography
    • Portable radiology
    • Home radiology
    • Reporting room
    • Veterinary
  • Preclinical
    • PET/SPECT/CT/OI
    • MRI
    • X-RAY IRRADIATORS
    • 2D X-RAY IMAGING
  • Scientific instruments
    • MICROSCOPY TECHNIQUES SEM, TEM, FIB-SEM, AFM, µCT
    • Consumables for Microscopy
    • SEM-FEG SEM-TEM-EBSD Sample Preparation Instruments.
    • Benchtop and floor-standing 3D X-ray micro-CT
    • XRD DIFFRACTOMETERS
    • X-RAY DIFFRACTOMETERS FOR SINGLE CRYSTALS
    • Electron diffractometry
    • MBE AND EBL PROCESS SYSTEMS
    • XPS SURFACE CHEMICAL ANALYSIS, AUGER ELECTRON SPECTROSCOPY, TOF-SIMS
    • METROLOGY FOR SEMICONDUCTOR TXRF, WDXRF
    • HIGH RESOLUTION ISOTOPE MASS SPECTROMETRY
    • NANOINDENTERS
    • PROFILOMETERS
    • TRIBOMETERS
    • X-RAY SPECTROMETERS
    • SAXS (Low Angle X-Ray Scattering) Systems.
  • Forensic
    • BALLISTIC IDENTIFICATION
    • FORGERY OF DOCUMENTS
  • Automotive
    • Electric Vehicle and Hybrid Powertrain Testing Solutions
    • HEV Transmission EOL Test Stand
    • Battery Testing
    • Conventional Engine & Powertrain Testing Solutions
    • Components
  • Fuel Cells & Hydrogen
  • Clean Room
    • Life Science Applications
    • Applications Industrial Sector
    • Scientific applications for research and universities
  • Training
  • Service & Validation
Bruker TI Premier
  1. Home
  2. Scientific Instruments
  3. Nanoindenters
  4. Bruker TI Premier

Bruker TI Premier

Nanoindenter

The TI Premier model is specifically designed to provide quantitative and highly reliable nanomechanical characterization within a compact platform.

Bruker
Request information

Product features


One-dimensional (1D) capacitive transducer, with

  • Risoluzione di spostamento normale <0.01 nm
  • Total indentation displacement in the vertical direction: ~50 mm
  • Maximum indentation depth: > 5 µm
  • Drifttermico <0,1 nm/s
  • Carico normale massimo: 10mN (con risoluzione <5nN), 30mNopzionale; intervallo di spostamento normale: da 0,2 nm a 5 µm
  • In-situSPM Imaging, con forza minima < 100nN
  • Maximum scan volume: > 60μmx 60μmx 4μm
  • Accuracy in probe positioning: ±25 nm

NanoWearTesting

  • Normal load range from 100nNto 1mN
  • Wear area size: from 4μma 60μm
  • Motorized XYZ translation slides with 150 mm x 150 mm x 50 mm stroke (with 50 nm resolution)
  • Digital electronic control architecture, DSP, FPGA
  • Optical microscope with 10X objective, digital zoom 0.5 X - 11 X
  • Maximum FOV: 3200μmx 2400μm
  • Minimum FOV: 145μmx 109μm
  • Insulation from the environment: passive antivibrational, acoustic, thermal

Feedback control package

  • Inclosedloop feedback control of normal load or displacement while nanoindentation or scratching is taking place
  • 78 kHz feedback loop rate

Possible options

  • Trasduttore capacitivo bidimensionale (2D), con carico laterale massimo 2mN(con risoluzione <250nN)
  • Performech®II package for dynamic mode/ XPM implementation having DSP architecture, FPGA with 1.2 MHz data sampling rate on all channels; 24 bit ADC, 20 bit DAC
  • Controllo delpiezo perImaging SPM integrato (<= 70nNforza di contatto)
  • Built-in lock-in amplifier

Feedback control package

  • Active anti-vibration system
  • Objectives for the 20 X, 50 X microscope
  • Multi-RangeNanoProbe™(special dinanoindentationand scratch heads)
  • MEMSxProbe transducers for ultra-low forces
  • Cooling/heating module (-10°C - 200°C)
  • xSol400,xSol600,xSol800 high-temperature heating modules
  • Electrochemical cell
  • Wide range dichuck
  • nanoDMA®III dynamic mechanical analysis
  • nanoECR®nanoinductive in-situ induction
  • Modulusmapping
  • TriboAE™ (in-situ-via-probe monitoring of acoustic signals generated by fracture and deformation events during the nanoindentation process)

The TI Premier model is specifically designed to provide quantitative and highly reliable nanomechanical characterization within a compact platform. Through the TI Premier, reliable quantitative nanomechanical and nanotribological characterization is possible, applicable to traditional materials, thin films, and advanced materials.

The TI Premier system is essential for basic and advanced nanomechanical testing using Hysitron's capacitive transducer technology for superior hardness and reduced modulus characterization. In addition, quantitative characterization of the tribological properties of materials is provided with the nanotensile technique. In-situ SPM imaging allows, along with the accuracy of nanoscale probe placement, topographic visualization of the surface prior to making a measurement: this provides a solid foundation for the highest reliability of the test to be performed.

Find out the specifications

View the brochure

Learn more about the product features on

Ask for more information

Schedule a call with one of our consultants


    I agree to the processing of my data according to the Privacy Policy

    Assing S.p.A.
    Via Edoardo Amaldi, 14
    00015 - Monterotondo, Rome - Italy
    Tel. +39 06 90 67 01 / Email: sales@assing.it
    Cap. Soc. € 2,500,000.00
    C.F. - 06725640582
    P. Iva - 01603091008
    SDI Unique Code - JUCMV14

    • Radiology
    • Preclinical
    • Scientific instruments
    • Automotive
    • Clean Room
    • Forensic
    • Training
    • Service & Validation
    • Who we are
    • Our Story
    • Certifications
    • Research and innovation projects
    • Work with us
    • Contact

    © 2026 Assing. All rights reserved.

    • Whistleblowing
    • Privacy Policy
    • Cookie Policy
    • Credits